PhaseFlow™ 

A modular cooling platform from Lennox, built for AI and high-density data centers. 

PhaseFlow™ helps you direct more power to compute, reduce water dependence and scale cooling capacity as demand grows. 

Up to 25%*

Lower Energy Use

Waterless

Zero Operational Water Use

Refrigerant-Flexible

CO₂ and Lower-GWP Options

130+ Years

of Lennox Thermal Expertise

HOW PHASEFLOW WORKS

A Refrigerant-Based Approach to Heat Rejection 

PhaseFlow™ operates in the heat rejection loop, providing a refrigerant-based platform that cools the process fluid responsible for rack-level heat removal. Unlike conventional approaches that rely on facility water and glycol infrastructure, it decouples facility heat rejection from load-side fluid requirements, so one platform serves air-cooled and liquid-cooled deployments. 

 

video-thumbnail.webp

THE PHASEFLOW™ ADVANTAGE

Efficient by Design. Flexible by Choice. 

Make cooling decisions around your site, workloads and operating priorities, not the limitations of a conventional architecture.

efficiency.svg
Up To 25% Lower Energy Use

Direct refrigerant delivery to CDUs eliminates the facility water loop, reducing cooling energy consumption by 10–25%*

  • Fewer heat-transfer steps than conventional chilled-water architectures 

  • More power available for IT workloads 

  • Additional efficiency potential with two-phase liquid cooling architectures. 

 

 

waterless.svg
Waterless

Eliminate operational water use in data centers with an air-cooled configuration.

  • No cooling towers or water treatment in waterless configurations 

  • Lower operating and maintenance costs 

  • Optional low-water adiabatic configuration for additional energy efficiency 

 

refrigerant-flexible.svg
Refrigerant Flexible

Choose from multiple refrigerant options to fit your site and sustainability objectives. 

  • All-natural CO₂ and lower-GWP HFO/HFC refrigerant options 

  • Flexibility to align with evolving refrigerant regulations 

  • Avoid lock-in to a single refrigerant 

 

cic-banner-image.webp

CUSTOMER INNOVATION CENTER

See It Run. Then Put It to Work.

See PhaseFlow™ operating at the Lennox Customer Innovation Center in Atlanta, Georgia. Book a half-day working session to experience a live demonstration, talk with our technical experts and explore the economics for your site. 

BUILT FOR WHAT COMES NEXT

Cooling that evolves with your data center needs

From evolving cooling strategies to growing capacity demands, PhaseFlow™ provides a future-ready, scalable and resilient platform configured around your site. Built to adapt over time, it helps protect today’s investment while preparing your cooling infrastructure for what comes next.

Air + Direct-to-Chip Cooling

A single refrigerant-based facility loop supports air cooling plus single and two-phase direct-to-chip cooling strategies.

direct-to-chip-cooling.webp

Scalable Capacity

Add cooling capacity as site demand grows through a modular skid-to-plant architecture.

scalable-capacity-blog-image.png

Tailored to Your Site

Configure capacity, cooling, redundancy and heat rejection to fit your site, climate and operational needs.

tailored-to-your-site.webp
multiple-supply.webp

Multiple Supply Temperatures

Accommodates different supply temperatures for air- and liquid-cooling requirements.

Built-In Redundancy

Provides baseline N+1 redundancy with concurrent maintainability and automated failover, with options for higher-redundancy architectures, including N+X and 2N.

build-in-redundancy.webp

CONTACT US

Talk to a Data Center Expert

Tell us about your site, cooling requirements and operating priorities. A Lennox data center expert can help you evaluate where PhaseFlow™ fits and identify the right next steps.

Stay Connected With

Lennox Data Center Solutions

Expert Insights. Practical Updates.

Follow on LinkedIn
  • AI & High-Density Cooling Trends

    Stay informed on emerging cooling technologies and infrastructure requirements.

  • Data Center Design Best Practices

    Access expert perspectives on efficiency, scalability, and reliability.

  • Product & Innovation Updates

    Learn about new solutions, case studies, and customer success stories.

FAQs

Find answers to common questions about PhaseFlow™ and data center cooling.

PhaseFlow™ is a modular, refrigerant-based cooling platform from Lennox® built for data centers facing higher heat loads, rising energy demands and evolving infrastructure needs. It supports air and liquid cooling and is designed to scale efficiently while helping reduce water dependence and support sustainability goals.

Water Efficient Data Center Cooling | Lennox Data Center Solutions